Bushings Delivered
Product Center
High Voltage Bushing Products | 12kV-550kV
RIP/RIF dry-type capacitive bushings for transformers, GIS, wall and oil-SF6 applications. IEC 60137 & GB/T 4109 certified.
Years Manufacturing
Certified
Railway Market Share
Dry-type bushing models for transformer, GIS and wall applications
Get Recommendation →
Oil-Air Transformer Bushing
12kV-550kV | 1A-8000ADry-type capacitive bushing for oil-immersed transformers with outdoor air-side connection.
View Details →
Oil-SF6 Transformer Bushing
40.5kV-550kV | 630A-8000ATransition bushing for transformer-to-GIS interfaces in compact substation layouts.
View Details →
Oil-Oil Transformer Bushing
40.5kV-550kV | 630A-8000AOil-oil capacitive bushing for transformer internal connections and special replacement projects.
View Details →
High Current Transformer Bushing
24kV-40.5kV | 12,500A-40,000AHigh-current bushing for generator transformers, furnace transformers and heavy industrial equipment.
View Details →
GIS Outlet Bushing
40.5kV-550kV | 1000A-8000AGIS outlet bushing for SF6 switchgear, substations and high-voltage power equipment interfaces.
View Details →
Wall Bushing
24kV-550kV | 630A-8000AWall penetration bushing for indoor-to-outdoor high-voltage transitions in power stations.
View Details →Technical specifications
Voltage class, CT mounting and typical application reference
Use the table below as an early selection reference. Final dimensions, creepage distance and conductor configuration should be confirmed against the transformer or GIS drawing.
| Rated Voltage (kV) | CT Mounting (mm) | Typical Application |
|---|---|---|
| 12 | 0 / 150 / 250 / 400 | Distribution transformers and compact substations |
| 24 | 0 / 150 / 250 / 400 | Medium-voltage transformer outlets and indoor equipment |
| 40.5 | 0 / 150 / 250 / 400 | Transformer, wall and industrial power equipment |
| 72.5 | 0 / 250 / 400 / 550 | Substation transformers and GIS transition projects |
| 126-170 | 250 / 400 / 550 | High-voltage grid transformers and replacement projects |
| 252-550 | 200 / 400 / 500 / 700 | EHV substations, rail power and critical grid nodes |
Application scenarios
Where Qixing bushings are typically used
Power Transformers
Bushings for oil-immersed power transformers from utility substations to industrial transformer rooms.
GIS Connections
Oil-SF6 and GIS bushings for compact grid equipment and transformer-to-switchgear interfaces.
Wall Penetration
FRP capacitive wall bushings for indoor and outdoor high-voltage transitions in power facilities.
Replacement Projects
Drawing-based and sample-based support for maintenance inventories and transformer retrofit work.
Model selection support
Need help selecting a bushing model?
Send your voltage, current and application — Mark Yan will reply with a recommendation within 24 hours.
Thank you! We'll respond within 24 hours.